Saral 300 is an enhanced metering solution for three-phase direct-connected installations. It is suitable for domestic, industrial and commercial applications.

Saral 300 is an accurate and reliable metering solution for the measurement of electrical energy three-phase four-wire networks and ensures revenue assurance, making it especially useful in areas where theft and fraud are prevalent

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Revenue protection

    • Advanced anti-tamper prevention, detection and deterrence
    • Revenue protected against wrong connections such as reversal, interchange of earth/neutral, or partial earthing
    • Extensive forensic information for detection and analysis of tamper attempts
    • Locking arrangement for incoming mains cable, to inhibit wiring tampers
  • Highlights

    • Meter reading in the absence of mains power
    • Integrated base and cover
    • Current and temperature profiled to help detect loose connections and attempts to burn
    • Walkby meter reading over BLE (Optional)
  • Benefits

    • Revenue protection against tamper and fraud
    • Quality-of-supply information
    • Peak and o-peak tari management
    • Stringent ingress protection, can be used outdoors
    • Low cost of ownership
    • Specification
    • Electrical

       

      Connection type

      3-phase 4-wire, direct connected

      Rated voltage

      230/240 V

      Impulse withstand

      10 kV, 2 Ω setup

      Current range

      5-30 A/10-60 A/10-100 A

      Frequency

      50 Hz, ± 5%

      Accuracy class

      Class 1.0

      Metrology lamp

      Two metrological LEDs for active and reactive energy

      Mechanical

       

      Dimensions (W x H x D)

      126 mm x 222 mm x 92 mm

      Enclosure material

      0.32 kg (approx.)

      Meter case:

      LEXAN 143/ 943 or equivalent

      Terminal block:

      LEXAN 500R/equivalent

      Weight:

      0.78 kg (approx.)

      Sealing provision

      One wire seal and one paper seal between body and terminal block, two on terminal block cover

      Environmental

       

      Ingress protection

      IP 54

      Insulation class

      Protective class II

      Temperature

      -10 °C to +60 °C (operating)

      -25 °C to +70 °C (storage)

      Humidity

      95% non-condensing

      Features

       

      Tariff rate registers

      Up to 8 rate registers, for configurable energy channels

      Maximum demand

      Up to 2 types, configurable across 8 registers

      Load survey

      Up to 240 days for 10 parameters, at 30 minutes integration period

      Communications

      Optical port for local communications,

      Options