Specification
Electrical | |
Auxiliary supply | 110-230 V AC/DC |
Internal relays | 2 nos. contact rating 230 V AC, 2 A |
Compliance | |
Standard | ISO 5198, ISO 4185, IEC61326-1, CISPR22, EN 61010-1:2001 |
Mechanical | |
Dimensions (W X H X D) | 144 x 144 x 172 mm |
Weight | 1.2 kg (approx.) |
Mounting type | Panel or wall mounting |
Material | Fire-retardant polycarbonate |
Environmental | |
Ambient temperature | -10°C to +60°C |
Ingress protection | IP 54 |
Humidity | 95% non-condensing |
95% non-condensing | |
Pump parameters | Pump efficiency, system efficiency, head and flow |
Electrical parameters | Drive power, voltage, current and frequency |
Display | 128 x 80 pixel graphical LCD, 81 x 53 mm, with green backlight |
Data logging | Up to 40 days for 15 parameters, with 15-minute integration period |