Specification
Electrical | |
Connection type | 1-phase 2-wires, active-neutral, direct connected |
Measuring elements | 2 elements |
Rated voltage | 230V, -20% to +15% |
Maximum voltage | 460V (L-N) continuous |
Impulse withstand | 12 kV, 9 J, as per NMI M6 |
Current range | 10-100A |
Frequency | 50 Hz ±5 |
Accuracy class | Class 1.0 (active energy), class 2.0 (reactive energy) |
Metrology lamp | Two metrological LEDs for active and reactive energy |
Compliance | |
Standards* | NMI M6-1, AS 62052.11, AS 62053.21, AS 62053.23, AS 62052.21, AS 62054.11 Exceeds minimum services specification as per the National Electricity Amendment (expanding competition in metering and related services. Rule 2015 No. 12) |
Data storage capacity | |
Energy/demand load profile | 395 days (per channel) at 30-minute interval (configurable), up to 12 channels, 65 days (per channel) at 5-minute interval (configurable), up to 4 channels |
Quality of supply (QoS) parameters | 90 days (per parameter) at 30-minute interval (configurable), up to 8 parameters, including average voltage, current, phase angle, temperature |
Switches/outputs | |
Mains supply contactor | 100A |
Auxiliary load control | 31.5A |