Specification
| Electrical | |
| Contact rating | 13 Amps 230V AC Suitable for immersion heaters up to 3kw | 
| Contact type | Micro-disconnection on control, disconnection to immersion heaters on double-pole rocker switch | 
| Supply | 230V 50Hz | 
| Environmental | |
| Pollution degree | Degree 2 normal situations | 
| Moisture protection | Ordinary | 
| Enclosure protection | IP30 | 
| Features | |
| Shock protection | Class 1 | 
| Live parts | Enclosed | 
| Operating temperature range | 0°c to 35°C | 
| Battery reserve | Approximately 2 years total power disconnection | 
| Clock | am/pm Indication Winter/Summer indication | 
| Programme options | Full 7-day programmming; Off-peak & Boost, up to three time periods each; Boost – programmable automatic boost and 1/2, 1, and 2-hour manual boosts | 
| Mechanical | |
| Dimensions | 170 x 115 x 60mm (excluding rocker switch) | 
| Radio | |
| Compliance | Bluetooth BLE compliant | 
| Operating frequency | 2.4 GHZ | 
| RF range | ~60m, line of sight | 
| Compliance | |
| Product Standard/Safety : BSEN / EN 60730-1, BSEN / EN 60730-2-7 RED Radio: ETSI EN 300 328 RED EMC: ETSI EN 301 489-1, ETSI EN 301 489-17, BS EN 60730-2-7  | 
|